Rapid real time PCR to distinguish between high risk human papillomavirus types 16 and 18. Cubie HA, Seager AL, McGoogan E,

Statistics from Altmetric.com

The authors would like to apologise for an error that occurred in the writing of this paper. In table 1 (25) two of the primer sequences were incorrect.

  • The sequence of GP6+ should have been as follows: GAAAAATAAACTGTAAATCATATTC.

  • The sequence of TS165 should have been as follows: TTTGTTACTGTTGTTGATACTACA.

All experiments reported in this study were performed with the correct primers and experimental data do not change as a result of this error.