Article Text

Download PDFPDF
Accurate molecular detection of melanoma nodal metastases: an assessment of multimarker assay specificity, sensitivity, and detection rate
  1. V Davids1,
  2. S H Kidson1,
  3. G S Hanekom2
  1. 1Department of Human Biology, Faculty of Heath Sciences, University of Cape Town and Groote Schuur Hospital, 7925, South Africa
  2. 2Department of Clinical Laboratory Sciences, Faculty of Heath Sciences, University of Cape Town and Groote Schuur Hospital
  1. Correspondence to:
 Dr G S Hanekom, Department of Clinical Laboratory Sciences, 6th floor, Chris Barnard Building, Anzio Road, Cape Town, 7925, South Africa;
 ghanekom{at}uctgsh1.uct.ac.za.

Abstract

Background: The application of lymphoscintigraphy followed by sentinel lymph node (SN) biopsy to patients with primary melanoma has revolutionised the ability to identify accurately, yet conservatively, those patients who harbour occult nodal metastases. The molecular detection of SN micrometastases facilitates the cost effective analysis of the entire SN using multiple markers. Currently, a lack of marker specificity is the main barrier preventing the molecular evaluation of SN tissue from becoming clinically applicable.

Aims: To develop a reproducible multimarker reverse transcription-polymerase chain reaction (RT-PCR) assay, with the emphasis on achieving high specificity for the accurate detection of melanoma metastases in nodal tissue.

Methods: Three pigment cell specific (PCS) markers—tyrosinase, Pmel-17, and MART-1—and one cancer testis antigen (CTA)—MAGE-3—were selected for use in a multimarker RT-PCR assay. The conditions for this assay were optimised.

Results: High specificity was achievable for each marker by optimising the PCR cycle number such that unwanted transcripts (that is, illegitimate transcripts and/or specific transcripts from other low abundance nodal cell types) remained undetectable in appropriate controls (normal visceral nodes). Tyrosinase was 100% specific at 40 PCR cycles, MAGE-3 and MART-1 at 35 PCR cycles, and Pmel-17 at 30 PCR cycles. Tyrosinase proved to be the most sensitive marker, detecting 10 melanoma cells in 0.1 g of nodal tissue.

Conclusions: Excellent reproducibility of the entire nodal processing and RT-PCR protocol for the detection of very low numbers of melanoma cells in nodal tissue was shown, although there is a risk of false positives using the PCS markers alone, because of an approximate 4–8.5% incidence rate of nodal nevi in melanoma draining SNs (these nevi being absent in all other normal nodes). MAGE-3 was shown to be the only marker that is not expressed by melanocytes. However, because not all melanomas express MAGE-3, it is recommended that more emphasis should be placed on the development of a panel of CTA markers to ensure a zero false positive rate and to provide optimum detection.

  • melanoma
  • prognosis
  • reverse transcription-polymerase chain reaction
  • sentinel lymph node
  • specificity
  • metastasis
  • AJCC, American Joint Committee on Cancer
  • CMC, circulating melanoma cells
  • CTA, cancer testis antigen
  • GAPDH, glutaraldehyde-3-phosphate dehydrogenase
  • H&E, haematoxylin and eosin
  • PBGD, porphobilinogen deaminase
  • PCS, pigment cell specific
  • RT-PCR, reverse transcription-polymerase chain reaction
  • SN, sentinel lymph node

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes